COOLING TOWER REPLACEMENT PARTS

|
R-130 SPRAY SYSTEM
|
|
MAINTENANCE FREE - OPTIMUM TOWER PERFORMANCE
The new spray system has several
unique features which enables optimum tower performance at all
times, with minimal maintenance. The most important feature is a dramatic
reduction in the number of nozzles. If you retrofit a 1000 ton tower built
before 1976, an R130 system requires only 30 nozzles compared to 1000 on
the original tower. A 1000 ton tower built after 1976 has 200 nozzles which
will again be reduced to 30 R130 nozzles.
See
a Demonstration Movie of how the
CTM R130 Spray System Retrofit
will save on Your Maintenance and Operating Costs... |
Back to top

|
BLADE TYPE ELIMINATORS
|
|
This durable inexpensive blade, PVC eliminator replaces wood or asbestos
eliminators.
|
Back to top

|
CELLULAR TYPE ELIMINATORS
|
|
The cellular PVC drift eliminators are stronger & more efficient than
the blade type eliminator.
|
Back to top

|
PVC
FILL MEDIA
|
This
state-of-the-art, high efficiency PVC honeycomb fill replaces
obsolete & inefficient corrugated steel fill, MNA asbestos
fill & wooden lath splash fill.
|
Back to top

|
CELLULAR
INLET REMOVERS
|
Replaces
obsolete & hazardous asbestos cement louvers & plywood
louvers. |
Back to top

|
DRIVE
FAN SHAFTS
|
The
new non corrosive composite graphite
drive shafts are stronger & lighter for
longer life & performance. Also available
hollow tube & solid fan shafts in mild steel
or s/steel for cooling towers, closed circuit
coolers & air handling units. |
Back to top

|
FAN
BLADES & HUBS
|
TUF-LITE® FIBERGLASS
COOLING TOWER FANS
Tuf-Lite® fans are constructed of light weight corrosion
resistant, fiberglass reinforced vinyl ester or epoxy resins.
Tuf-lite II® are available in adjustable pitch or energy
saving Auto Variable® pitch hubs, for new applications
or retrofit existing. |
Back to top

|
FAN
WHEELS
|
Heavy
duty fan wheels for all makes & models of cooling towers,
closed circuit coolers & air handling units.
FAN CLAMPS & BALANCING CLIPS:
Complete range of fan clamps & balancing clips are in stock
for all fan wheels & balancing requirements.
|
Back to top

|
SAFETY
LADDERS PLATFORMS & HANDRAILS
|
Safety
regulations require access ladders, safety cages, perimeter handrails & walkways
as per Ontario Ministry of Labour Bill 208 standards. All in
stock & available
for immediate installation & hot dipped galvanized after
fabrication.
Download
the Ontario Fixed Access Ladders Engineering Data Sheet PDF |
Back to top

|
GEAR
REDUCERS
|
New & rebuilt
with complete warranties, for all makes of cooling towers. Gear
Reducer parts, lubrication and accessories available. A complete
range of half couplings, neoprene bushings, boston couplings
are available in stock. |
Back to top

|
MOTORS
- NEW & REBUILT
|
Cooling
tower motors operate in hars conditions. Windings must be triple
dipped & baked. Customized drain holes & seals required
on motors in discharge air streams. All motors have full warranties. |
Back to top

|
BEARINGS
|
Split
sleeve & solid sleeve bearings pillow block & flange
mounted bearings are in stock at ALL times for all makes & models
of towers & air handling units. |
Back to top

|
ACCESSORIES
|
Stainless
steel & hot dipped galvanized hardware, pre-pressure
treated marine grade plywood & quality grade lumber. Polyurethane
caulking & sealants. Two part solvent free polymeric coating
system for cooling tower interiors & air handling units.
ALL IN STOCK.
|
Back to top

|
FIRE
RETARDANT FIBERGLASS
|
FIBERGLASS
CASING & LOUVERS:
Fire retardant fiberglass casing, corner
rolls, access doors & louvers
(8oz, 12oz, 16oz & 24oz) all colours available.
|
Back to top

|
FLOAT
VALVES & FLOATS
|
Heavy
duty float valves complete with aluminum bar and stainless steel
adapter for convenient lateral and vertical adjustment. |
Back to top

|
SIDE
STREAM FILTRATION
|
Provides
continuous filtering of cooling or process waters to remove suspended
solids such as airborne silt, sand organic matter, as well as
waterborne contaminant's such as scale & corrosion products,
microbiological & other organic matter. |
Back to top

|
ELECTRICAL
ACCESSORIES
|
Cold
water basin immersion heaters, automatic level controls. Variable
frequency drives. Two speed motor control panels, slow closing
solenoid valves. Anti-vibration limit switches. |
Back to top

Larger than existing heavy,
steel, circular doors
Greater access for maintenance
or emergencies

Confined Space OCCUPATIONAL HEALTH AND SAFETY ACT
O. Reg. 629_05
|
NEW!
CTM SAFETY ACCESS DOORS
|
Non-Corrosive
Access Doors Designed With Operator Safety
in Mind!
Optimally Sized to Suit Each Cooling Tower Installation!
Exclusively
from CTM!
CTM Safety Access Doors promote operator safety
and save maintenance dollars into the bargain!
CTM Safety Access Doors are larger than present
17" or 22" circular steel doors, are non-corrosive, optimally
sized to suit each cooling tower and easily retro-fitted into
existing large and small tower installations.
CTM Safety Access Doors promote full and safe
access to the cold water basin for cleaning and maintenance -
often without the need to actually enter the tower!
Adding two CTM Safety Access Doors on larger
forced draft towers will allow easy access for maintenance crew
and allow safe extraction of personnel in the event of an emergency.
"Awkward and dangerous access to the cold
water basin is a thing of the past with CTM Safety Access Doors."
Call CTM Today:
1 800 311-1200
|
Back
to top
|
 |